PLUG-IN-READY OPERATION
The Royal Sovereign hand dryer provides maximum flexibility when
installing the hand dryer. The hand dryer is plug and play ready.
Simply connect 3 wires to the terminal slots - Positive (L), Negative
(N), and Ground (T). A hard-wire option is also available, for those
who do not want to use the supplied power supply. Simply use your
own power cable (14 AWG or better)
INSTALLATION INSTRUCTION - STEP 1
Plug-and-play Ready Operation
To prepare the hand dryer for "plug and play" ready operation, proceed as follows:
1. Use the supplied Allen key and remove the stainless steel hand dryer cover.
2. Remove the circuit board cover of the circuit board. Run the supplied power cable though the back power supply hole.
3. Attach the negative cable to the negative terminal (labeled N).
4. Attach the ground cable to the ground terminal (labeled T).
5. Attach the positive cable to the positive ground terminal (labeled L).
6. Proceed to the second step of installation.
Hard Wire Operation
You have the option of utilizing the supplied power cord, or utilizing you own wires. To utilize the supplied power cord,
proceed as per the instructions "Plug and Play Ready Operation" to utilize your own wires.
1. Install 1/2" electrical connector in the pack part of the housing in the hole located above the circuit board.
2. Feed wires though the power supply hole (14 AWG or better); tighten clamp down on wire.
3. Connect the wires to the slots on the terminal marked NLT.

LN
Inductive head socket
120V~
Heating
wire
M
Motor